ISO 17025 accredited

Granite Surface Plate Calibration Granite Surface Plate Refinishing

 

 

Request A Quote

surface_plate.jpg

Precision Granite Calibration

 

Capabilities-

8 to 161  inches diagonal

 

Learn more about Surface Plates

 

Standards Followed for Surface Plate Calibration:

  • GGG-P-463C
  • MIL STD 45662A
  • NAVIR 17-20MD-14
  • T.O. 33K6-4-443-1
  • T.B. 9-5220-212-40
  • Manufacturers Specifications
  • Customer Specifications

Check out our Dimensional Calibration Page for more capabilities.

 

 

Frequently Asked Questions

Gage ID Number

Description and Size of Gage

Calibration Cycle

Check Points (if not specified, we adhere to our quality policy)

Gage ID is the unique identifier you use to identify the specific piece of equipment.

Calibration Cycle is the interval between calibrations.

 We use this information to provide a sticker for the calibrated instrument to show when it was calibrated and when you want it calibrated again.

 

 

 

 

YES!

Please include power cords, leads, and any accessories necessary for us to perform the calibration.

 

 

All ISO 17025 accredited calibrations are traceable through NIST or another NMI(National Metrology Institute) to the SI Unit. 

Calibration certificates include as-found data, as-left data, and measurement uncertainty.

Alliance Calibration

11402 Reading Road

Cincinnati, OH 45241

We do offer onsite calibration service within a 150-mile radius. Not all calibrations are best suited for onsite calibration.

Please contact Customer Service with your specific question.

The minimum order is $100.

No.

    Still, Have Questions?

        Request A Quote

        You Might Want To Read.......

        We are excited to announce that as of June 2022, Alliance Calibration is now a Transcat company!

        Transcat is a leading provider of accredited calibration, repair, inspection, and laboratory instrument services and a value-added distributor of professional grade handheld test, measurement, and..

        June 17, 2022

        What is force calibration?

        Force calibration is the process of verifying and adjusting the accuracy of a force measuring device by comparing the device's readings to known standards. Force calibration is vital in manufacturing..

        May 30, 2022

        How Are Bore Gauges Used In Medical Device Manufacturing?

        Bore gauges are precision tools used to measure the internal diameter of various objects, including medical devices. In medical device manufacturing, bore gauges ensure that components such as pipes..

        May 16, 2022

        Common Uses For Linear Scales

        What are linear scales? Linear scales are devices that measure various things. This guide will explore more common uses for linear scales in greater detail.

        May 2, 2022