ISO 17025 accredited

Current Calibration

 

 

Request A Quote

Current Shunt Calibration

 Capabilities:

AC/DC Current- Measure: 10mA to 200A

AC Current Frequency- Measure: 40 Hz to 1 kHz

AC/DC Current- Source: 3.3 mA to 200A

AC Current Frequency- Source: 20Hz to 1 kHz

 

Check out our Electrical Calibration Page for more capabilities.

 

Brands we calibrate:

Extech
Ideal
Keysight
Craftsman
Amprobe
Fluke
Westward
Milwaukee
Flir
UEI
General Tools
Greenlee
Yokogawa

and more....

What is Current?

Current is the rate at which electrons flow past a point in a complete electrical circuit. At its most basic, current = flow.

An ampere (AM-pir), or amp, is the international unit used for measuring current. It expresses the quantity of electrons (sometimes called "electrical charge") flowing past a point in a circuit over a given time.

A current of 1 ampere means that 1 coulomb of electrons—that's 6.24 billion billion (6.24 x 1018) electrons—is moving past a single point in a circuit in 1 second. The calculation is similar to measuring water flow: how many gallons pass a single point in a pipe in 1 minute (gallons per minute, or GPM).What is current

Symbols used for amps:

A = amperes, for a large amount of current (1.000).
mA = milliamperes, a thousandth of an amp (0.001).
µA = microamperes, a millionth of an amp (0.000001).

In formulas such as Ohm's Law, current is also represented by I (for intensity).

Amps are named for French mathematician/physicist Andrè-Marie Ampére (1775-1836), credited for proving:

  • A magnetic field is generated around a conductor as current passes through it.
  • The strength of that field is directly proportional to the amount of current flowing.

Electrons flow through a conductor (typically a metal wire, usually copper) when two prerequisites of an electric circuit are met:

  1. The circuit includes an energy source (a battery, for instance) that produces voltage. Without voltage, electrons move randomly and fairly evenly within a wire, and current cannot flow. Voltage creates pressure that drives electrons in a single direction.
  2. The circuit forms a closed, conducting loop through which electrons can flow, providing energy to any device (a load) connected to the circuit. A circuit is closed (complete) when a switch is turned to the ON, or closed, position (see diagram at the top of this page).

Current, like voltage, can be direct or alternating.

Direct current (dc):

  • Represented by the symbols Direct current symbol 1 or Direct current symbol 2 on a digital multimeter.
  • Flows only in one direction.
  • Common source: batteries or dc generator.

Alternating current (ac):

  • Represented by the symbols Alternating current symbol 1 or Alternating current symbol 2 on a digital multimeter.
  • Flows in a sine wave pattern (shown below); reverses direction at regular intervals.
  • Common source: household electrical receptacles powered by a public utility.
What is current?
Above: Alternating current in the form of a sine wave.

Most digital multimeters can measure dc or ac current no higher than 10 amps. Higher current must be scaled down with a current clamp accessory, which measures current (from .01 A or less to 1000 A) by gauging the strength of the magnetic field around a conductor. This permits measurements without opening the circuit.

Any component (lamp, motor, heating element) that converts electrical energy into some other form of energy (light, rotating motion, heat) uses current.

When additional loads are added to a circuit, the circuit must deliver more current. The size of conductors, fuses and the components themselves will determine how much current will flow through the circuit.

Amperage measurements are normally taken to indicate the amount of circuit loading or the condition of a load. Measuring current is a standard part of troubleshooting.

Current flows only when voltage provides the necessary pressure to cause electrons to move. Different voltage sources produce different amounts of current. Standard household batteries (AAA, AA, C and D) produce 1.5 volts each, yet larger batteries are capable of delivering greater amounts of current.

Reference: Digital Multimeter Principles by Glen A. Mazur, American Technical Publishers.

 

 

Frequently Asked Questions

Gage ID Number

Description and Size of Gage

Calibration Cycle

Check Points (if not specified, we adhere to our quality policy)

Gage ID is the unique identifier you use to identify the specific piece of equipment.

Calibration Cycle is the interval between calibrations.

 We use this information to provide a sticker for the calibrated instrument to show when it was calibrated and when you want it calibrated again.

 

 

 

 

YES!

Please include power cords, leads, and any accessories necessary for us to perform the calibration.

 

 

All ISO 17025 accredited calibrations are traceable through NIST or another NMI(National Metrology Institute) to the SI Unit. 

Calibration certificates include as-found data, as-left data, and measurement uncertainty.